Extron electronic Switch System 5 IP Series User Manual

SyStem SwItcherS  
System 5 IP Series  
®
Five Input A/V Switchers with IP Link Ethernet Control  
1U, full rack width metal enclosure — The System 5 IP can be easily mounted into  
any rack or podium with included mounting brackets.  
common FeAtureS  
Video inputs: two inputs configurable for composite video, S-video, or RGBHV on  
female BNC connectors; two inputs configurable for composite video or S-video  
on female BNC and 4-pin mini DIN connectors; RGBHV on front panel female  
15-pin HD connector  
Internal international power supply — The 100-240VAC, 50/60 Hz, universal power  
supply provides worldwide power compatibility.  
deScriPtion  
Audio inputs: balanced/unbalanced audio on captive screw connectors; stereo  
audio on front panel female 3.5 mm stereo mini jack  
The Extron System 5 IP is a five input, one output integrated A/V active switcher that  
provides an all-in-one, affordable solution for single projector A/V installations in classrooms,  
boardrooms, conference rooms, and multimedia environments. It includes such features as  
configurable inputs, easy-to-use IR learning, customized display control via RS-232, relays  
for room control, an integrated 40-watt, rms, audio amplifier, and IP Link® Ethernet monitoring  
and control.  
Video outputs: RGBHV, RGBS, RGsB, RsGsBs, S-video, and composite video on  
female BNC connectors  
Audio outputs: balanced/unbalanced audio on captive screw connectors;  
amplified stereo audio on insulated screw terminals  
350 MHz (-3 dB) RGB video bandwidth — Maintains signal integrity.  
Universal Projector Control  
Universal display control via RS-232 or IR — Provides compatibility with virtually any  
controllable display device.  
The System 5 IP offers two methods of projector control: RS-232 or IR. The switcher can learn  
IR signals from remote controls. This enables the switcher to communicate with the display  
and sources such as VCRs and DVD players. IR learning makes setup and operation simple and  
customizable. Virtually any RS-232 controllable projector or display device can be used with  
the System 5 IP. Extron creates and administers a wide selection of commonly used projector  
control drivers that enable the System 5 IP to control basic projector functions such as power  
and input selection. Users can create their own drivers or go to the Extron Web site to download  
RS-232 drivers configured for the latest and most popular projectors. In addition, a custom  
configuration mode is available to allow for user-defined IR or RS-232 commands.  
Four IR/Serial control ports  
Digital Input Monitoring Port  
Pre-configured drivers  
Six configurable relays for room control — The System 5 IP is equipped with six  
internal relays to control lighting, screen settings, and other device functions. The relays  
may be controlled through the front panel, IR 402 remote, SCP control panel, or RS-232.  
Remote IR learning capabilities for DVD, VCR, and projector control — The System 5 IP  
is capable of performing IR learning which enables it to control various source devices when  
using optional IRCMs Infrared Control Modules such as the IRCM-DV+.  
Room Control  
The System 5 IP also offers room control capability, so room lighting, screen settings, and other  
device functions may be controlled through the switcher's six internal relays. In addition, a digital  
input monitoring port is provided, allowing for enhanced monitoring via sensors and switches,  
or streamlined automation of triggering events, or other functions. By providing projector  
control, room control, universal compatibility with displays, and system audio capabilities, the  
System 5 IP consolidates functions that would typically require up to six different products into  
one integrated solution.  
RS-232 serial control port — Using serial commands, the System 5 IP can be controlled  
and configured via the Extron Windows®-based control program, or integrated into third-  
party control systems. Extron products use the SIS- Simple Instruction Set command  
protocol, a set of basic ASCII code commands that allow for quick and easy programming.  
Supports all IR and RS-232 preconfigured IP Link drivers  
IP Link® Ethernet monitoring and control — An IP integration technology developed  
by Extron specifically engineered to meet the needs of professional A/V environments  
that enables the System 5 IP to be controlled and proactively monitored over a LAN,  
WAN, or the Internet.  
Fixed and Variable Preamp Line Level Outputs  
The System 5 IP provides fixed and variable line level audio outputs on captive screw  
connectors for use with an external amplifier or self-powered speakers. Fixed audio outputs  
are especially effective when used with external mixers, amplifiers, and assistive listening  
devices. Variable audio outputs enable the audio signal levels to be adjusted using the  
switcher's volume control.  
7.25 MB flash memory — The System 5 IP's built-in Web server features 7.25 MB  
of flash memory for storing the GlobalViewer® management application and any user  
customized Web pages.  
Remote control capabilities with optional IR 402 remote and SCP 104 and  
SCP 226 Secondary Control Panels  
Integrated Stereo Audio Amplifier  
Fixed and variable preamp line level audio outputs  
Stereo or dual mono audio output - selectable  
The System 5 IP is available with or without an internal 40-watt audio amplifier, 2 x 20 watts rms,  
to drive 4 or 8 ohm speakers. The unit can also be set for dual mono mode where it sums  
the left and right input signals together and drives the same mono signal to both the left and  
right outputs.  
Triple-Action Switchingfor RGB delay — Blanks the screen during switching of RGB  
signals to eliminate visible switching transitions.  
Integrated inactivity timer turns off projector after user-defined time  
Tri-colored, backlit buttons  
IP Link® Ethernet Control  
The System 5 IP is equipped with Extron's IP Link®, an IP integration technology specifically  
engineered to meet the needs of professional A/V environments — from small K-12 classrooms  
to large universities and businesses. IP Link provides these advantages:  
Optional CFG configuration cable available for loading drivers, configuring audio  
input levels, and video selection type  
Continued  
264  
USA West  
USA east  
© 2008 Extron Electronics. All rights reserved.  
Pricing and specifications may change without notice.  
+1.714.491.1500 / +800.633.9876  
+1.714.491.1517 FAX  
+1.919.863.1794 / +800.633.9876  
+1.919.863.1797 FAX  
 
SyStem SwItcherS  
System 5 IP Series  
System 5 IP Series Accessories  
incLuded AcceSSorieS  
modeL deScriPtion  
PAGe  
PArt #  
NETXC M-M  
MBD 149  
Male to Male RJ-45 Network Crossover Cable, 6' (1.8 m). . . . . . . . . . . . . . . . . . . . . . . . . page 797  
1U, Full Rack Width, Rack Mount and Through-Desk Kit for  
Four-Piece Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 817  
26-591-01  
70-077-03  
oPtionAL AcceSSorieS  
modeL deScriPtion  
PAGe  
PArt #  
SCP 104  
SCP 226  
IRCM-DV+  
IR 402  
IR Emitter and Shield Kit  
IR Emitter and Shield - Dual Kit  
IR Link  
CFG Cable  
UC50' (50' / 15 m)  
MLSC 406/506/5IP-35'  
Secondary Control Panel for MLC 104 IP Plus and System 5 IP. . . . . . . . . . . . . . . . . . page 273  
Secondary Control Panel for MLC 226 IP and System 5 IP . . . . . . . . . . . . . . . . . . . . . . . page 400  
Dual-Function DVD and VCR IR Control Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 393  
Handheld IR Remote Control for System 5 IP and MLC 226 IP . . . . . . . . . . . . . . . . . . . page 415  
IR Emitter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 281  
IR Emitter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 281  
Wall-Mountable IR Signal Repeater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 281  
9-pin D Female to 2.5 mm TRS Configuration Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 282  
Female 9-pin D Connector to Unterminated - Captive Screw Ready . . . . . . . . . . . . . n/a  
60-672-02  
60-671-02  
70-220-02  
70-207-01  
70-283-01  
70-283-02  
60-404-02  
70-335-01  
26-518-01  
One Pre-terminated SY VGA and Composite Video Cable, and One S-Video  
Adapter Cable - Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 444  
I/O Descriptor Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . n/a  
42-097-35  
33-953-02  
System 5 IP Labels  
Audio inPut  
SPeciFicAtionS  
Number / Signal type . . . . . . . 4 stereo or mono, balanced/unbalanced (inputs 1-4)  
1 stereo or mono, unbalanced (input 5)  
Connectors. . . . . . . . . . . . . . . . (4) 3.5 mm captive screw connectors, 5 pole (inputs 1-4)  
(1) 3.5 mm mini audio jack (tip, ring, sleeve) (input 5)  
Video  
Gain. . . . . . . . . . . . . . . . . . . . . . Unity  
Bandwidth . . . . . . . . . . . . . . . . 350 MHz (-3 dB), fully loaded  
Video inPut  
Impedance . . . . . . . . . . . . . . . . >10k ohms unbalanced  
Nominal level. . . . . . . . . . . . . . -10 dBV (316 mVrms)  
Input gain adjustment . . . . . . -40 dB to +30 dB, adjustable per input  
Number/signal type . . . . . . . . 1 RGBHV, RGBS, RGsB, RsGsBs  
2 RGBHV, RGBS, RGsB, RsGsBs, S-video, or composite video  
2 S-video or composite video  
Audio outPut — Line LeVeL  
Connectors. . . . . . . . . . . . . . . . (1) 15-pin HD female (RGB)  
Number / Signal type . . . . . . . 2 stereo or mono, balanced/unbalanced (1 fixed and 1 variable)  
Connectors. . . . . . . . . . . . . . . . (2) 3.5mm captive screw connectors, 5 pole  
Impedance . . . . . . . . . . . . . . . . 50 ohms unbalanced, 100 ohms balanced  
2 x 5 female BNCs (RGB, S-video, or composite video)  
2 x 1 female BNC (composite video) and (1) 4-pin mini DIN (S-video)  
Impedance . . . . . . . . . . . . . . . . 75 ohms  
Horizontal frequency. . . . . . . . 15 kHz to 145 kHz  
Vertical frequency. . . . . . . . . . 30 Hz to 170 Hz  
Nominal level. . . . . . . . . . . . . . -10 dBV (316 mV) or +4 dBu (1.23 V) (configurable)  
Audio outPut  
Power AmPLiFier (Amplifier modelS only)  
Number / Signal type . . . . . . . 1 stereo or mono  
Connector. . . . . . . . . . . . . . . . . (1) 4 position screw terminal  
Sensitivity. . . . . . . . . . . . . . . . . -22 dBV (80 mVrms, -19.8 dBu) for max. power output (adjustable)  
Power bandwidth at rated maximum power output  
4 ohm output. . . . . . . . . . . . . . . 10 Hz to 20 kHz, 0.5% THD  
8 ohm output. . . . . . . . . . . . . . . 20 Hz to 20 kHz, 0.8% THD  
Drive / Full power out. . . . . . . 40 watts; 20 watts (rms) per channel, 4 or 8 ohm load  
Protection. . . . . . . . . . . . . . . . . Input limiting, thermal, short circuit  
Video outPut  
Number/signal type . . . . . . . . 1 RGBHV, RGBS, RGsB, RsGsBs  
1 S-video  
1 composite video  
Connectors. . . . . . . . . . . . . . . . 5 female BNCs (RGB)  
2 female BNCs (S-video)  
1 female BNC (composite video)  
Nominal level. . . . . . . . . . . . . . 1 Vp-p for Y of S-video, and for composite video  
0.7 Vp-p for RGB  
controL / remote  
Switcher  
0.3 Vp-p for C of S-video  
Serial control port. . . . . . . . . . 2 RS-232: 1 rear panel 9-pin female D connector,  
1 front panel 2.5 mm stereo mini jack  
Minimum / Maximum levels  
RGB . . . . . . . . . . . . . . . . . . . . . . Analog: 0.3 V to 1.5 Vp-p (follows input)  
S-video, composite video . . . . . Analog: 0.4 V to 2.0 Vp-p (follows input)  
Impedance . . . . . . . . . . . . . . . . 75 ohms  
Return loss. . . . . . . . . . . . . . . . <-40 dB @ 5 MHz  
DC offset. . . . . . . . . . . . . . . . . . 5 mV with input at 0 offset  
Switching type. . . . . . . . . . . . . Triple-Action™ (RGB delay)  
Ethernet control port . . . . . . . 1 RJ-45 female  
Ethernet data rate. . . . . . . . . . 10/100Base-T, half/full duplex with autodetect  
Ethernet protocol . . . . . . . . . . ARP, DHCP, ICMP (ping), TCP/IP, Telnet, HTTP, SMTP  
Web server. . . . . . . . . . . . . . . . 7.25 MB nonvolatile user memory  
controL  
reLAy  
Number / Type . . . . . . . . . . . . . 6 momentary or latching (configurable via software)  
Connectors. . . . . . . . . . . . . . . . (3) 3.5 mm captive screw connectors, 3 pole  
Contact rating . . . . . . . . . . . . . 24 V, 1A  
Sync  
Input type. . . . . . . . . . . . . . . . . RGBHV, RGBS, RGsB, RsGsBs  
Output type . . . . . . . . . . . . . . . RGBHV, RGBS, RGsB, RsGsBs (follows input)  
Input level . . . . . . . . . . . . . . . . 2.0 V to 5.0 Vp-p  
Output level . . . . . . . . . . . . . . . 5.0 Vp-p, unterminated  
Input impedance . . . . . . . . . . . 10k ohms  
controL  
Projector  
Projector control port  
(RS-232) . . . . . . . . . . . . . . . . . . (1) 3.5 mm captive screw connector, 3-pole  
Output impedance. . . . . . . . . . 75 ohms  
Max. propagation delay . . . . . 30 ns  
Max. Rise/fall time . . . . . . . . . 4 ns  
controL  
IR / Serial control ports . . . . . (4) 3.5 mm captive screw connectors, 2-pole  
Programmable: RS-232 ( 5 V), or TTL level (0 to 5 V) infrared up to 1 MHz  
PeriPherAL equiPment  
Audio  
GenerAL  
Gain  
Power . . . . . . . . . . . . . . . . . . . . 100 VAC to 240 VAC, 50/60 Hz, 50 watts, internal, universal  
Temperature / Humidity . . . . . Storage -40° to +158°F (-40° to +70°C) / 10% to 90%, noncondensing  
Operating +32° to +122°F (0° to +50°C) / 10% to 90%, noncondensing  
Rack mount . . . . . . . . . . . . . . . Yes, with included brackets  
Enclosure type. . . . . . . . . . . . . Metal  
Enclosure dimensions . . . . . . 1.75" H x 17.5" W x 9.4" D (1U high, full rack wide)  
4.4 cm H x 44.4 cm W x 23.9 cm D  
Product weight . . . . . . . . . . . . 6.0 lbs (2.7 kg)  
Shipping weight . . . . . . . . . . . 11 lbs (5 kg)  
DIM weight  
USA / Canada . . . . . . . . . . . . . . 10 lbs (5 kg)  
International. . . . . . . . . . . . . . . . 11 lbs (5 kg)  
Vibration. . . . . . . . . . . . . . . . . . ISTA 1A in carton (International Safe Transit Association)  
Listings. . . . . . . . . . . . . . . . . . . UL, CUL  
Compliances . . . . . . . . . . . . . . CE, FCC Class A, VCCI, AS/NZS, ICES  
MTBF. . . . . . . . . . . . . . . . . . . . . 30,000 hours  
Warranty. . . . . . . . . . . . . . . . . . 3 years parts and labor  
NOTE: All nominal levels are at 10%. Specifications are subject to change without notice.  
Lineout. . . . . . . . . . . . . . . . . . . . Unbalanced output: 0 dB; balanced output: +6 dB  
Preamp . . . . . . . . . . . . . . . . . . . Unbalanced output: -6 dB; balanced output: 0 dB at max. volume  
Frequency response,  
amplifier models  
Power amp (4 or 8 ohm) . . . . . . 20 Hz to 20 kHz, 0 dB to -1.5 dB @ 1 watt output  
Lineout/preamp. . . . . . . . . . . . . 20 Hz to 20 kHz, 0 dB to -0.5 dB  
Frequency response,  
non amplifier models  
Lineout/preamp. . . . . . . . . . . . . 20 Hz to 20 kHz, 0 dB to -0.5 dB  
THD + Noise. . . . . . . . . . . . . . . <0.15% @ 1 kHz at max. power output  
S/N at max. power output or  
line level output, unweighted  
Power amp  
(amplifier models only) . . . . . . . >80 dB at 10 Hz to 22 kHz  
Preamp . . . . . . . . . . . . . . . . . . . >-100 dB at 20 Hz to 20 kHz  
Lineout. . . . . . . . . . . . . . . . . . . . >-110 dB at 10 Hz to 22 kHz  
Crosstalk . . . . . . . . . . . . . . . . . <-80 dB @ 1 kHz, fully loaded  
CMRR . . . . . . . . . . . . . . . . . . . . >80 dB @ 20 Hz to 200 Hz, >60 dB @ 20 Hz to 20 kHz  
Continued  
266  
USA West  
USA east  
+1.919.863.1794 / +800.633.9876  
+1.919.863.1797 FAX  
© 2008 Extron Electronics. All rights reserved.  
+1.714.491.1500 / +800.633.9876  
+1.714.491.1517 FAX  
Pricing and specifications may change without notice.  
 

Echo Saw PAS 225SB User Manual
Edelbrock Automobile Parts 15041 User Manual
Extron electronic Stereo Amplifier FOX 500 DA6 User Manual
Extron electronic Switch SW4 ARxi User Manual
FieldServer Computer Drive FS 8700 78 User Manual
Frigidaire Ventilation Hood PL36WC41EC User Manual
FujiFilm Digital Camera 16324446 User Manual
Fujitsu All in One Printer fi 434PR User Manual
Fujitsu Switch MB88121 SERIES User Manual
Garland Range U36 2G24R User Manual